<cliOutput>
  <opRet>0</opRet>
  <opErrno>0</opErrno>
  <opErrstr/>
  <volInfo>
    <volumes>
      <volume>
        <name>raid6</name>
        <id>b79fa2e5-d739-4ea1-b2a8-5925294e1e78</id>
        <status>1</status>
        <statusStr>Started</statusStr>
        <brickCount>2</brickCount>
        <distCount>2</distCount>
        <stripeCount>1</stripeCount>
        <replicaCount>2</replicaCount>
        <type>2</type>
        <typeStr>Replicate</typeStr>
        <transport>0</transport>
        <bricks>
          <brick>gprfs035-10ge:/mnt/brick1/brick</brick>
          <brick>gprfs036-10ge:/mnt/brick1/brick</brick>
        </bricks>
        <optCount>3</optCount>
        <options>
          <option>
            <name>performance.read-ahead-page-count</name>
            <value>16</value>
          </option>
          <option>
            <name>performance.write-behind</name>
            <value>on</value>
          </option>
          <option>
            <name>performance.write-behind-window-size</name>
            <value>4194304</value>
          </option>
        </options>
      </volume>
      <volume>
        <name>raid1</name>
        <id>d94c7b29-0644-487a-a66c-fb55a28f313f</id>
        <status>1</status>
        <statusStr>Started</statusStr>
        <brickCount>12</brickCount>
        <distCount>2</distCount>
        <stripeCount>1</stripeCount>
        <replicaCount>2</replicaCount>
        <type>5</type>
        <typeStr>Distributed-Replicate</typeStr>
        <transport>0</transport>
        <bricks>
          <brick>gprfs033-10ge:/mnt/brick-sdb/brick</brick>
          <brick>gprfs034-10ge:/mnt/brick-sdb/brick</brick>
          <brick>gprfs033-10ge:/mnt/brick-sdc/brick</brick>
          <brick>gprfs034-10ge:/mnt/brick-sdc/brick</brick>
          <brick>gprfs033-10ge:/mnt/brick-sdd/brick</brick>
          <brick>gprfs034-10ge:/mnt/brick-sdd/brick</brick>
          <brick>gprfs033-10ge:/mnt/brick-sde/brick</brick>
          <brick>gprfs034-10ge:/mnt/brick-sde/brick</brick>
          <brick>gprfs033-10ge:/mnt/brick-sdf/brick</brick>
          <brick>gprfs034-10ge:/mnt/brick-sdf/brick</brick>
          <brick>gprfs033-10ge:/mnt/brick-sdg/brick</brick>
          <brick>gprfs034-10ge:/mnt/brick-sdg/brick</brick>
        </bricks>
        <optCount>2</optCount>
        <options>
          <option>
            <name>diagnostics.count-fop-hits</name>
            <value>on</value>
          </option>
          <option>
            <name>diagnostics.latency-measurement</name>
            <value>on</value>
          </option>
        </options>
      </volume>
      <count>2</count>
    </volumes>
  </volInfo>